IMPLEMENTASI AUTOMATIC DUST DETECTOR UNTUK MENINGKATKAN EFISIENSI PENGOPERASIAN DUST SUPPRESSION PADA TRANSFER TOWER 0 DI PLTU PAITON 9 (Studi Kasus di PT. UBJ O & M Paiton 9)

Maulana, Adam Febrian (2020) IMPLEMENTASI AUTOMATIC DUST DETECTOR UNTUK MENINGKATKAN EFISIENSI PENGOPERASIAN DUST SUPPRESSION PADA TRANSFER TOWER 0 DI PLTU PAITON 9 (Studi Kasus di PT. UBJ O & M Paiton 9). Skripsi thesis, Universitas Panca Marga Probolinggo.

[img]
Preview
Text
COVER SKRIPSI Adam Febrian Maulana.pdf

Download (131kB) | Preview
[img] Text
DAFTAR ISI Adam Febrian Maulana.pdf
Restricted to perpustakaan UPM

Download (451kB)
[img]
Preview
Text
ABSTRAK Adam Febrian Maulana.pdf

Download (7kB) | Preview
[img] Text
BAB I Adam Febrian Maulana.pdf
Restricted to perpustakaan UPM

Download (203kB)
[img] Text
BAB II Adam Febrian Maulana.pdf
Restricted to perpustakaan UPM

Download (323kB)
[img] Text
BAB III Adam Febrian Maulana.pdf
Restricted to perpustakaan UPM

Download (547kB)
[img] Text
BAB IV Adam Febrian Maulana.pdf
Restricted to perpustakaan UPM

Download (1MB)
[img] Text
BAB V Adam Febrian Maulana.pdf
Restricted to perpustakaan UPM

Download (165kB)
[img] Text
DAFTAR PUSTAKA Adam Febrian Maulana.pdf
Restricted to perpustakaan UPM

Download (134kB)

Abstract

The operation of dust suppressor and dust collector was operating semimanually by pressing the power button on the local panel during the initial unloading of coal material from the barge or stockpile, where local operators manage several large areas. This research is carried out on the implementation of Automatic Dust Detector for Dust Suppression operational at Paiton Unit 9 power plants with the aim of increasing the efficiency of operator and equipment performance. We use House of Quality (HOQ) as a determinant of the priority scale for technical response to be implemented, namely the addition of an Automatic Dust Detector. The results obtained showed a decrease in the calculation of the dust suppression operating time, i.e. from 5 hour 54 minutes to 5 hour 6 minutes, from 1005,36L/barge to 869,04L/barge for water consumption, and 1L/barge to 0,86L/barge for chemical use. Furthermore, the implementation of the Automatic Dust Detector can significantly increase efficiency at least 15% from operating time difference.

Item Type: Thesis ( Skripsi)
Uncontrolled Keywords: Dust suppression, dust, efficiency
Subjects: Fakultas Teknik
Divisions: Manajemen
Depositing User: Admin Perpustakaan
Date Deposited: 26 Oct 2021 02:00
Last Modified: 26 Oct 2021 02:00
URI: http://repository.upm.ac.id/id/eprint/2317